We began to develop and produce the side channel blowers from ten years ago, after so many years, we have the professional and complete team, from developing, producing to sales. And each production procedure is operated in our own workshop, tooling making, die casting, stamping, high precision machining, assembling and automatic spraying, so we could control the quality, cost and delivery date better.
In 2017, we are rated as the top 100 enterprises in Wenling.(No. 51)
OUR CHARACTERISTICS !
oil free, Insulation class is F, Protection class is IP55.
Dual frequency 50HZ and 60HZ are available
Made of die cast aluminum ADC12.
Dual usage: compressor and vacuum (suction and blow).
Virtually maintenance free, with sealed long life bearings.
Smart design and low noise
ATEX explosion proof motor is available for all the blowers.
Anti corrosion blower and special color could be customized.
The energy efficiency for the motor of 2.2kw, 3kw and 5.5kw could reach IE2 standard.
一、原理 旋涡气泵增氧技术采用旋涡气泵(高压风机)将空气送入输气管道输气管道将空气送入微孔曝气管或是其他曝气装置,由于其孔径小,可产生大量微细化气泡从管壁冒出分散到水中,而且上升速度缓慢气泡在水中移动行程长与水体接触充分气液相间氧分子交换充分而且还增加了水流的旋转和上下流动。水流的上下流动将上层富含氧气的水带入底层同时水流的旋转流动将微孔管周围富含氧气的水向外扩散实现养殖池水的均匀增氧。具有溶氧、改善养殖水体生态环境、提高放养密度、增加养殖产量、降低能耗、使用安全和操作方便等优点。
二、结构 旋涡气泵增氧设施主要有旋涡气泵、主管、PVC塑料管、支管PVC塑料或橡胶软管、微孔曝气管(或曝气盘,气泡石)、止回阀、球阀等组成。旋涡气泵常用功率有7.5KW、5.5KW、4KW 、3.0 KW、2.2KW、1.5KW。旋涡气泵(高压风机)连接主管、主管连接支管---橡胶软管---连接曝气管(曝气盘,气泡石等曝气装置均可)。
三、安装 以微孔管为例,安装方式主要有两种一是盘式安装法。配备功率为0.25kw/667㎡将曝气管固定在用钢筋直径为4~6mm做成的盘框上曝气管盘的总长度8~15m安装3~4只每667㎡,并固定离池底10~20㎝。二是条式安装法。配备功率为0.25 kw每667㎡,曝气管总长度为10~40m左右,管间距10m左右高低相差不超过10㎝并固定离池底15~20㎝。两种安装方式为常见形式,盘式安装简单快捷,一般推荐盘式安装。条式安装,工程量大,分布均匀。
四、使用方法 根据水体溶氧变化的规律确定开机增氧的时间和时段。 一般4~5月份,阴雨天半夜开机。6~10月下午开机2~3小时,日出前后开机2~3小时,连续阴雨或低压天气,夜间21:00~22:00时开机,持续到第2天中午。养殖后期,勤开机促进水产养殖对象生长。有条件的进行溶氧检测。适时开机,以水体溶氧在6~8毫克/升为佳。
五、 注意事项 旋涡气泵(高压风机)设置安装时应注意通风、散热、遮阳及防淋。曝气管、盘,安装应保持在同一水平面,以利供气增氧均衡。微孔增氧设备安装结束后,应经常开机使用,防止微孔堵塞。每年养殖周期结束后,应及时清洗。由于养殖的品种、养殖的密度、养殖的面积不同旋涡气泵增氧系统管路的铺设各不相同,如果管路铺设不好 将影响增氧的效果。微孔管铺设安装应注意以下几点要求
1、应根据水面面积和形状设计管路的铺设方式。 2、按照设计要求准备好各种材料如三通、堵头、塑料线管。塑料线管尽量选择内黑外蓝以防管内生澡堵塞微孔管。 3、安装时,各管接头处要用胶或管箍密封防止漏气。4、应尽量曝气管出气量均匀一条曝气管长度好控制在20m以下铺设时末端应前端15cm左右以末端出气均匀。 5、曝气管尽量不和淤泥接触以免堵塞。 6、主机尽量安装在主管道的中间以各管道供气量相同。主机进气口附近不要有杂物以免堵塞。 7、安装完毕应进行调试。将主机打开逐根曝气管进行调试调整曝气管高度、方向直到整条微孔管曝气均匀 8、如安装调试期间旋涡风机运行半小时无持续发热安装成功,如有异样关机检查。
风机的主要故障有:
1、轴承箱剧烈振动。
解决方案
A:风机轴与电机轴不平行,皮带轮槽错位;
B:机壳或进风口与叶轮磨擦;
C:基础的刚度不够或不牢固;
D:叶轮铆钉松动或轮盘变形;
E:叶轮轴盘与轴松动;
F:机壳与支架、轴承箱与支架、轴承箱盖与座等联接螺栓松动;
G:风机进出气管道的安装不良;
H:转子不平衡。
2、轴承温升过高。
解决方案
A:轴承箱剧烈振动;
B:润滑油脂质量不良、变质、含有灰尘、粘砂、污垢等杂质;
C:轴承箱盖、座联接螺栓之紧力过大或过小;
D:轴与滚动轴承安装歪斜,前后二轴承不同心;
E:滚动轴承损坏。
3、电机电流过大和温升过高。
解决方案
A:开车时进气管内阀门或节流阀未关严;
B:流量超过规定值,或风管漏气;
C:风机输送气体密度过大;
D:电机输入电压过低或电源单相断电;
E:受轴承箱剧烈振动的影响;
F:风机工作情况恶化,或发生故障。
1: 鼓风机风量计算方式
Q=60VA
Q=(风量)=㎥/min
V=(风速)=m/sec
A=(截面积)= ㎡
2.风机压力常用换算公式
1Pa=0.102mmAq
1mbar=10.197mmAq
1mmHg=13.6mmAq
1psi=703mmAq
1Torr=133.3 Pa
1Torr=13.3 mmAq
mmAq=1.333mbar
3常用单位换算表-风量
1㎥/min(CMM)=1000l/min=35.31ft3/min(CFM)
Q 常用单位换算表-风量
1m3/min(CMM)=1000 l/min = 35.31 ft3/min(CFM)
Q 常用名词说明
(1)标准状态:为20℃,压力760mmHg,相对湿度 65%。此状态简称为STP,一般在此状态下1m3之空气重量为1.2kg。
(2)空气之压力:为当地大气压计所显示的大气压力再加上表压力之和,一般用kgf/m2或mmaq来表示。
(3)基准状态:为0℃,压力760mmHg,相对湿度0%。此状态简称为NTP,一般在此状态下1m3之空气重量为1.293kg。
Q 压力
(1)静压(Ps):所谓静压就是流体施加于器具表面且与表面垂直的力,在风机中一般是由于重力与风扇之推动所造成,在使用上常以kgf/m2或mmaq来表示,且可以直接经过量测取得。而在风机之风管中,任何方向之静压值皆为定值且也有正负之分,若静压值为正则表示风管目前正被胀大,若静压值为负则表示风管目前正受挤压。
(2)动压(Pv):所谓动压就是流体在风管内流动之速度所形成之压力,在使用上常以kgf/m2或mmaq来表示.
(3)全压(PT):所谓全压就是静压与动压之和,在使用上常以kgf/m2或mmaq来表示。在风机中全压值是属固定,并不会因风管缩管而产生变化.
Q 风压与温度
温度变化会影响空气之密度。故在其他条件不变的情况下,温度变化时,其风压依下面之关系加以校正,以获得标准情况下之风压值:
P = P’(273 + t/293) (mm Aq)
同样,当空气密度变更时,其风压值可作如下之修正:
P = P’(1.2/γ ) (mm Aq)
式中,等号右侧之值如P’、t、γ等之实测压力、温度与空气密度。
Q 压力与速度的关系
多大的压力就固定有多大的速度,不可能压力不变速度会改变,同理,不可能速度不变压力会改变。
Pv=4.83 × r × V2 / 2g Pv: 动压(mmAq) r: 空气比重(kg/m3)
g:重力加速度(m/s2)=9.8 V:风速(m/s)
设rO为标准状态时的比重量(1.293 kg/Nm3)
r=rO × 273 / (273+T) T:气体温度
V=[(Pv/4.83)×(2g/r)]√